<LOGO>
FM Transmitter Measurement Report
Created: 2025-07-31 04-06-13
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 2/5, 54 dBuV SANDELS
Pilot RDS Phase Difference
6.1 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
17 kHz 30 kHz 732 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
2,9 dBr 4,90 dBr 6,4 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
92.0, 94.7, 106.4, 107.5 MHz -
FM Scope Max at: 30 kHz MIN: 17 kHz % above 76 kHz: 0,0000 Acquired: 2025/07/31 4.05.10 Total samples: 732 Equivalent time: 0:00:36 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 20 40
FM Scope MAX: 6,4 dBr MIN: 2,9 dBr AVE: 4,90 dBr % above 12,2 dBr: 0,0 Last value: 4,8 dBr (2025/07/31 4.05.09) 03.52 03.54 03.56 03.58 04.00 04.02 04.04 0 2 4 6 Pm [dBr]